0.005° High-Precision RS485 Inclinometer

Model: DR-INC-300R

Accuracy: ±0.005° (at room temperature)

Resolution: 0.0007° (at room temperature)

Measuring Range: ±30°

Number of Axes: Dual-axis (X+Y)

Output Interface: RS485, Modbus RTU Protocol

Application Scenarios: Ideal for industrial attitude control in construction machinery, bridge structural monitoring, wind turbine tower monitoring, and other industrial scenarios.

Drksir Certification and contact

Description

The DR-INC-300-R is a high-precision inclinometer with 0.005° absolute accuracy and RS485 output, built for wind turbine towers, transmission masts, and industrial structures, where settlement and verticality drift appear as fractions of a degree. This high-precision inclinometer covers a selectable ±5° / ±10° / ±20° / ±30° range on both axes and resolves 0.0007°. Modbus RTU over RS485 feeds a PLC, SCADA system, or data logger directly. The IP67 / IP68 (customizable) housing and -40°C ~ +85°C rating suit permanent outdoor installation, and the ±30° default model ships ready to mount.

Key Specifications

Parameter Specification
Measuring Axis Dual-axis X & Y
Measuring Range ±5° / ±10° / ±20° / ±30° (optional, default ±30°)
Absolute Accuracy 0.005°
Resolution 0.0007°
Sampling Frequency 100 Hz
Power Supply DC 9~36V
Operating Current 30 mA @ DC 12V
Communication Interface RS485 (Modbus RTU)
Operating Temperature -40°C ~ +85°C
Protection Grade IP67 / IP68 (customizable)
Average Service Life ≥55,000 hours
Cable Standard 1.5 m 4-core shielded cable

Where This Sensor Is Used

  • Wind turbine tower verticality — tower inclination and foundation tilt on onshore turbines, measured continuously from commissioning onward. The 0.005° absolute accuracy and 0.0007° resolution pick up the slow differential settlement that eventually shows as a tower out of plumb.
  • Transmission tower and monopole inclination — long-term tilt trend on power transmission masts, telecom monopoles, and lighting columns, where the ±30° range covers the full deflection budget with room to spare.
  • Industrial structure attitude monitoring — steel frames, silos, and large skid-mounted equipment where alignment changes with load and thermal cycling.
  • Precision machine tool leveling — bed flatness and column verticality checks where a 0.005° repeatability target is tighter than a machinist’s level can resolve.
  • High-precision laser platform leveling — optical benches and laser reference platforms that must hold their angle while fixtures and supports move on them.

Why Choose Drksir

  • 15+ years designing and manufacturing tilt sensors for industrial and infrastructure monitoring
  • 3,000+ projects delivered across civil engineering, renewable energy, and transportation
  • Full range of industrial inclinometers from 0.1° to 0.001° accuracy, sharing one Modbus RTU register layout
  • In-house MEMS design and signal conditioning — not a rebranded OEM module
  • IP67 / IP68 protection options for harsh environment installation
  • Average service life ≥55,000 hours
  • 24-month warranty and lifetime application engineering support

How It Compares to Alternatives

  • Versus electrolytic tilt sensors — faster response, no fluid temperature sensitivity, no need to level the unit at install
  • Versus LVDT-based inclinometers — smaller form factor, no moving parts, immune to vibration-induced wear
  • Versus the 4-20mA version of the same sensor — identical mechanics and accuracy; RS485 carries several sensors on one bus and returns digital values with diagnostics, while 4-20mA suits analog input cards and very long cable runs
  • Versus consumer-grade MEMS modules — industrial -40°C ~ +85°C rating, IP-rated housing, factory calibration instead of uncalibrated raw output

Installation & Wiring

Mount the sensor on a flat, rigid surface (steel bracket or concrete anchor recommended). For highest accuracy, align the sensor’s X-axis to the primary direction of expected tilt.

The sensor uses a 4-core shielded cable for power and data:

 

RS485 type inclinometer electrical connection diagram

 

RS485 type inclinometer electrical connection diagram

For RS485 cable runs over 100 m, use shielded twisted pair and terminate the shield at one end only. Maximum recommended cable length is 1,200 m at 9600 baud.

OEM/ODM & Customization

Standard units ship from stock within 5 business days. Custom measuring ranges (±5° / ±10° / ±20° alternate to default ±30°), cable lengths, connector types, and protection-grade options (IP67 vs IP68) are available for OEM/ODM orders starting at 50 units. Typical custom lead time is 15-25 business days. Engineering drawings, communication protocol documentation, and integration support are provided free of charge.

FAQ

Q: Which measuring range should I select?

A: Select the smallest range that covers your expected tilt. Accuracy stays at 0.005° across all four options (±5° / ±10° / ±20° / ±30°), so the choice is about arc, not precision. Tower verticality and foundation settlement normally sit inside ±10°; the ±30° default leaves headroom for construction-phase movement and for installations whose mounting surface is not yet aligned. The default SKU ships with ±30°; other ranges are configured at the factory on request.

Q: What if I need a different accuracy or measuring range?

A: The wired inclinometer family covers 0.1° to 0.001° in one housing family and one register layout. For sub-millidegree structural work, step up to the 0.001° Ultra-High Accuracy RS485 Inclinometer (±5° / ±10° / ±20° / ±30°, 0.0005° resolution). For a wider arc on construction machinery, the 0.01° Industrial-Grade RS485 Inclinometer measures ±10° / ±30° / ±60° / ±90°. For general leveling and vehicle work at ±90°, the 0.1° General-Purpose RS485 Inclinometer is the lower-cost entry point. Switching tier does not change your integration code.

Q: What’s the difference between this sensor and the 4-20mA version?

A: Identical mechanics, accuracy, and dimensions. The RS485 version outputs digital data via Modbus RTU; the 0.005° High-Precision 4-20mA Inclinometer outputs a current loop proportional to tilt, preferred where PLC analog inputs are already in place or where long cable runs in electrically noisy environments are required.

Q: Does the sensor require recalibration in the field?

A: No field recalibration is required for normal operation. For safety-critical tower or structural work we recommend periodic verification against a reference fixture; the interval depends on your monitoring standard.

Q: Can the sensor be used in submerged installations?

A: The IP68 protection option (customizable) is specified for continuous immersion. The qualified depth and duration depend on the sealing configuration — request the datasheet for the figures for your installation.

Get a Quote

📧 Email: sales@drksirsensor.com | 💬 WhatsApp: +86-135-1581-0281

Send us your required quantity, measuring range, output interface, and application scenario. We respond within one business day with pricing, datasheet, and lead time.